Description |
| |
Specifications: |
| |
|
Operation Environment: |
| |
Power: AC220V, 50HZ Temperature: 5 ? ~40 ? |
| |
Humidity: =95% Pressure: 86~106kPa |
| |
|
Scope: |
| |
Adult, pediatric and neonate patients |
| |
|
Performance Specifications |
| |
Display: 9.4” color TFT, 12.1”color TFT |
| |
Resolution: 640X480 800X600 |
| |
Trace: 7 waveforms (max) |
| |
Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s |
| |
Indicator: Power indicator light; QRS beep and alarm sound |
| |
Interface: Parameter cable interface; Power input socket; |
| |
|
External VGA interface for connection of an alternate display |
| |
Battery: Built-in and rechargeable, lasting for maximum 4 hours |
| |
Trend time: 1~72 hours |
| |
Alarm: User-adjustable High and Low audible and visual alarm |
| |
Networking: Connected to central monitoring system |
| |
Recorder: Built-in, thermal array; Plethysmogram waveform: 1 channels; |
| |
Record mode: manual, on alarm, time-defined, etc. |
| |
Record width: 50mm |
| |
Print speed: 25mm/s |
| |
|
ECG: |
| |
Input: 5-lead; RA; LA; RL; LL; V |
| |
Lead selection: I; II; III; avR; avL; avF; V; MCL |
| |
Gain selection: x0.5; x1; x2; x4 |
| |
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s |
| |
Heart Rate range: Adult:25~250bpm; Neonate/child: 25~250bpm |
| |
CMMR: Diagnostic mode: 90dB; Monitoring/operating mode: 110dB |
| |
Accuracy: ±2bpm |
| |
Resolution: 1bpm |
| |
Filter: Diagnostic mode: 0.05-130Hz; Monitoring mode: 0.5-40Hz; |
| |
Surgical mode: 1-20Hz |
| |
Scaling signal: 1mV, 5% |
| |
Alarm range: 20~250bpm |
| |
ST segment detection: Measurement range: -2.0mV~2.0mV |
| |
Alarm range: -2.0mV~2.0mV |
| |
|
Specifications: |
| |
Operation Environment: |
| |
Power: AC220V, 50HZ Temperature: 5 ? ~40 ? |
| |
Humidity: =95% Pressure: 86~106kPa |
| |
|
Scope: |
| |
Adult, pediatric and neonate patients |
| |
|
External VGA interface for connection of an alternate display |
| |
Battery: Built-in and rechargeable, lasting for maximum 4 hours |
| |
Trend time: 1~72 hours |
| |
Alarm: User-adjustable High and Low audible and visual alarm |
| |
Networking: Connected to central monitoring system |
| |
Recorder: Built-in, thermal array; Plethysmogram waveform: 1 channels; |
| |
Record mode: manual, on alarm, time-defined, etc. |
| |
Record width: 50mm |
| |
Print speed: 25mm/s |
| |
|
ECG: |
| |
Input: 5-lead; RA; LA; RL; LL; V |
| |
Lead selection: I; II; III; avR; avL; avF; V; MCL |
| |
Gain selection: x0.5; x1; x2; x4 |
| |
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s |
| |
Heart Rate range: Adult:25~250bpm; Neonate/child: 25~250bpm |
| |
CMMR: Diagnostic mode: 90dB; Monitoring/operating mode: 110dB |
| |
Accuracy: ±2bpm |
| |
Resolution: 1bpm |
| |
Filter: Diagnostic mode: 0.05-130Hz; Monitoring mode: 0.5-40Hz; |
| |
Surgical mode: 1-20Hz |
| |
Scaling signal: 1mV, 5% |
| |
Alarm range: 20~250bpm |
| |
ST segment detection: Measurement range: -2.0mV~2.0mV |
| |
Alarm range: -2.0mV~2.0mV |
| |
|
NIBP: |
| |
Method: Automatic oscillometric |
| |
Operation modes: Manual/Automatic |
| |
Auto measure time: Adjustable |
| |
Measurement unit: mmHg/kPa selectable |
| |
Measurement types: Systolic; Diastolic; Mean |
| |
|
SpO2: |
| |
Measurement range: 0-100% |
| |
Resolution: 1% |
| |
Accuracy: ±2% (80-100%); 0-60% |
| |
Alarm range: 0-100% |
| |
|
Respiration: |
| |
Method: Ra-LL impedance |
| |
Measurement range: 1-99rpm |
| |
Alarm range: 1-99rpm |
| |
|
Temperature: |
| |
Measurement range: 25-45 ? |
| |
Resolution: 0.1 ? |
| |
Accuracy: 0.2 ? |
| |
Channel: 1 channel; T1, T2 |
| |
|
Pulse Rate: |
| |
Range: 0-254bpm |
| |
Resolution: 1bpm |
| |
Accuracy: 1bpm |
| |
Alarm range: 20-250bpm |
| |
Standard parameters: ECG; RESP; NIBP; SpO2; 1-TEMP; PR |